myerseng  
myerseng
 
home
myerseng about us
myerseng catalog
 
antennas: stock
antennas: custom
radios
connectors: stock
connectors: custom
RF cables: stock
RF cables: custom
myerseng products info
antennas
radios
connectors
rf cables
myerseng design services
antennas
radios
embedded RF
systems
connector
RF cables
software/DSP
myerseng quotation
myerseng downloads
myerseng jobs
 
 
 
myerseng
 
 
GIF ANIMATION
 
 
  HOME                CATALOG INDEX              CUSTOM RADIOS/ANTENNAS
 
UHF NARROWBAND RADIO DATA LINKS AND MODEMS
advance preliminary specifications

NOTE: Specifications, Prices, Terms and Availability are subject to change without notice or liability. Standard MEI Terms and Conditions apply. All prices are FOB Factory

            TRANSMITTERS                                                                       RECEIVERS

 

Transmitters,  200 MHz to 2000 MHz:

Model:UTX-xxxx-101E / -102E / -103E for embedded applications
Model:UTX-xxxx-101S / -102S / -103S stand alone unit

 
  • Frequency: 200 MHz to 2000 MHz, example 418.000 MHz, P/N UTX-0418-101, Standard: 315 MHz, 418 MHz, 434 MHz, 868 MHz, 914 MHz
  • Frequency source: Crystal controlled
  • Output RF power: 1 mW, 0 dBm, optional Power Amplifiers up to 10 Watts available
  • Maximum duty: 100%
  • Modulation: 5 kHz peak FSK
  • Data rate: 5 kbps (-101), 10 kbps (-102), 20 kbps (-103)
  • Data interface: RS-232, RS-422
  • Power supply: +5 to +10 VDC
  • Output impedance: 50 ohms
  • Projected availability: 2007

    Model:UTX-xxxx-201E / -202E / -203E for embedded applications
    Model:UTX-xxxx-201S / -202S / -203S stand alone unit
    Options: +SCR (scrambled), +RND (pseudo-randomized period)

  • Frequency: 200 MHz to 2000 MHz, example 418.000 MHz, P/N UTX-0418-201, Standard: 315 MHz, 418 MHz, 434 MHz, 868 MHz, 914 MHz
  • Frequency source: Crystal controlled
  • Output RF power: 0.1 mW, -10 dBm
  • Maximum duty: 0.1%, limited by regulations
  • Duration of transmission: 10 ms, fixed
  • Minimum transmit period: 10 seconds (6 times per minute)
  • Maximum transmit period: 24 hours (once a day)
  • Modulation: 5 kHz peak FSK
  • Data per transmission: 1 byte (-201), 2 bytes (-202), 4 bytes (-203)
  • Data interface: RS-232, RS-422
  • Power supply: +3 to +10 VDC, designed for multi-year continual operation on a single coin cell battery
  • Output impedance: 50 ohms to high impedance, designed to work with MEI antennas UTXL-xxxx-2nn
  • These transmitters are ideally suited for alarm systems and low data remote sensing applications, where periodic battery replacement is either difficult or not economical. Use with URX-xxxx-301/2/3+BRST receivers for best performance.
  • Projected availability: 2007
    back to top of page
  • Receivers,  200 MHz to 2000 MHz:

    Model: URX-xxxx-101E / -102E / -103E for embedded applications
    Model: URX-xxxx-101S / -102S / -103S stand alone unit

    • Frequency: 200 MHz to 2000 MHz, example 418.000 MHz, P/N URX-0418-101, Standard: 315 MHz, 418 MHz, 434 MHz, 868 MHz, 914 MHz
    • Frequency source: Crystal controlled with AFC (Automatic Frequency Centering)
    • Sensitivity: -118 dBm (version -101)
    • IP3: -10 dBm
    • Bandwidth: 15 kHz
    • Data rate: 5 kbps (-101), 10 kbps (-102), 20 kbps (-103)
    • Data interface: RS-232, RS-422
    • Power supply: +5 to +10 VDC
    • Input impedance: 50 ohms
    • Projected availability: 2007


    Model: URX-xxxx-201E / -202E / -203E for embedded applications
    Model: URX-xxxx-201S / -202S / -203S stand alone unit

    • Frequency: 200 MHz to 2000 MHz, example 418.000 MHz, P/N URX-0418-202, Standard: 315 MHz, 418 MHz, 434 MHz, 868 MHz, 914 MHz
    • Frequency source: Crystal controlled with AFC (Automatic Frequency Centering)
    • Sensitivity: -123 dBm (version -201)
    • IP3: -5 dBm
    • Bandwidth: 15 kHz
    • Data rate: 5 kbps (-201), 10 kbps (-202), 20 kbps (-203)
    • Data interface: RS-232, RS-422
    • Power supply: +5 to +10 VDC
    • Input impedance: 50 ohms
    • Projected availability: 2007


    Model: URX-xxxx-301E / -302E / -303E for embedded applications
    Model: URX-xxxx-301S / -302S / -303S stand alone unit
    Options: +BRST (burst mode), +SCR (scrambled), +RND (pseudo-random period)

    • Frequency: 200 MHz to 2000 MHz, example 418.000 MHz, P/N URX-0418-303, Standard: 315 MHz, 418 MHz, 434 MHz, 868 MHz, 914 MHz
    • Frequency source: Crystal controlled with AFC (Automatic Frequency Centering)
    • Sensitivity: -125 dBm (version -301)
    • IP3: 0 dBm
    • Rejection ratio for all unwanted spurious, image, harmonic and IF responses: 80 dB
    • Adjacent channel rejection ratio: 80 dB
    • Second adjacent channel rejection ratio: 100 dB
    • Bandwidth: 15 kHz
    • Data rate: 5 kbps (-301), 10 kbps (-302), 20 kbps (-303)
    • Data interface: RS-232, RS-422
    • Power supply: +5 to +10 VDC
    • Input impedance: 50 ohms
    • Projected availability: 2007
      back to top of page


     
     
    NOTICE: All information on this site is copyright property of Myers Engineering International, Inc. Any and all information
    herein contained may not be used for other than its intended informational purpose, or in any manner detrimental to MEI.
    (C) 1996-2001, 2006 by Myers Engineering International, Inc.
    Send your comments or suggestions for improving this site to Webmaster.

    Template Designed By: Custom Website Templates